PFA Trace Analysis Labware
PFA Nitrogen Blowdown System 4-Position 6-Position Corrosion Resistant Multi Sample Evaporator with Customizable PFA Valves
Item Number : PL-CP50
Price varies based on specs and customizations
- Material Composition
- High-Purity Perfluoroalkoxy (PFA)
- Configuration
- 4/6-Position or Fully Customizable
- Max Operating Temperature
- 260°C
Shipping:
Contact us to get shipping details Enjoy On-time Dispatch Guarantee.
Why Choose Us
Easy ordering process, quality products, and dedicated support for your business success.
Product Overview



This high-purity PFA nitrogen blowdown system represents the pinnacle of sample concentration technology for laboratories requiring absolute purity and chemical resistance. Engineered primarily for the evaporation of aggressive solvents and the concentration of sensitive samples, the equipment utilizes a stream of inert nitrogen gas to rapidly lower the vapor pressure over the liquid surface. By eliminating all metallic components in the fluid path and gas distribution assembly, this system ensures that ultra-trace analysis remains free from secondary contamination, a critical requirement for modern mass spectrometry and spectroscopy workflows.
Designed specifically for industries such as semiconductor manufacturing, environmental geochemistry, and pharmaceutical research, the unit excels in handling concentrated mineral acids, including hydrofluoric acid (HF) and aqua regia. Its modular architecture allows for the simultaneous processing of multiple samples, significantly increasing throughput without compromising the integrity of the analytical process. The robust construction is tailored for high-demand industrial environments where equipment is subjected to continuous exposure to corrosive vapors and elevated temperatures.
Reliability is at the core of this system's engineering. Every component, from the distribution manifold to the individual blowdown needles and valves, is crafted from premium-grade fluoropolymers. This ensures a long operational lifespan and consistent performance under the most demanding conditions. The unit provides procurement teams and laboratory managers with a reliable, durable solution that reduces replacement costs and maintains the highest standards of safety and chemical inertness in the workplace.
Key Features
- Ultra-High Purity PFA Construction: The entire system is fabricated from high-purity perfluoroalkoxy (PFA), a material renowned for its exceptional chemical inertness and lack of additives or plasticizers, preventing sample contamination during the concentration process.
- Customizable Multi-Position Manifolds: Available in standard 4-position and 6-position configurations, the system can be customized to accommodate any number of sample bottles, ensuring the setup perfectly matches specific laboratory throughput requirements.
- Precision-Machined PFA Valves: Each position is equipped with a dedicated, CNC-machined PFA valve that provides granular control over nitrogen flow rates, allowing for simultaneous processing of samples with varying volumes or volatility.
- Zero-Leakage Fluid Connections: Utilizing advanced CNC fabrication techniques, the fittings and connections within the system are designed for a perfect fit, ensuring a secure, leak-proof gas delivery path even at high flow rates.
- Exceptional Thermal Stability: The PFA components are capable of withstanding operating temperatures up to 260°C, making the system suitable for high-temperature evaporation processes and ensuring structural integrity in heated environments.
- Superior Corrosion Resistance: Unlike stainless steel or coated aluminum systems, this unit is completely immune to corrosion from strong acids, bases, and organic solvents, making it the ideal choice for trace metal analysis.
- Integrated PFA Blowdown Bottles: The system is designed to work seamlessly with matching PFA bottles, which offer a smooth internal surface finish to maximize sample recovery and minimize cross-contamination between runs.
- Ergonomic and Modular Design: The modular nature of the system allows for easy cleaning, maintenance, and the replacement of individual components, ensuring the equipment can be adapted as laboratory needs evolve.
- Metal-Free Gas Path: By ensuring that the nitrogen gas only contacts perfluorinated materials, the risk of introducing metallic ions or atmospheric particulates into the sample is virtually eliminated.
Applications
| Application | Description | Key Benefit |
|---|---|---|
| Semiconductor Trace Analysis | Concentration of ultra-pure chemicals and wafer cleaning solutions for ICP-MS analysis. | Prevention of metallic contamination at the ppt level. |
| Geochemical Digestion | Evaporation of hydrofluoric and perchloric acid after rock sample digestion. | Total resistance to aggressive mineral acids. |
| Environmental Monitoring | Concentration of water and soil extracts for the detection of heavy metals and pollutants. | Consistent recovery rates for trace volatile components. |
| Pharmaceutical Quality Control | Solvent removal from active pharmaceutical ingredients (APIs) during purity testing. | Inert fluid path prevents degradation of sensitive compounds. |
| Isotope Geochemistry | Preparation of high-purity samples for thermal ionization mass spectrometry (TIMS). | Maximum material cleanliness for precise isotopic ratios. |
| Forensic Toxicology | Concentration of biological extracts for complex drug screening and chemical analysis. | Reliable solvent evaporation without sample loss. |
| Petrochemical Testing | Analysis of trace additives and contaminants in specialized fuels and lubricants. | Robust performance in the presence of organic solvents. |
Technical Specifications
| Feature Group | Parameter | Specification (PL-CP50 Series) |
|---|---|---|
| Material Properties | Primary Material | High-Purity Perfluoroalkoxy (PFA) |
| Thermal Resistance | Up to 260°C (500°F) | |
| Chemical Compatibility | Universal resistance to acids, bases, and solvents | |
| System Configuration | Position Options | 4-Position, 6-Position, or Custom Arrays |
| Control Mechanism | Individual PFA Needle Valves (PL-CP50-V) | |
| Port Connections | CNC Machined PFA Compression Fittings | |
| Dimensions & Customization | Bottle Compatibility | Standard PFA Bottles or Custom Sizes |
| Manifold Design | Customizable spacing and height adjustments | |
| Gas Inlet | Standard 1/4" or 6mm PFA Tubing Connection | |
| Performance | Gas Flow Control | Precision adjustable per position |
| Leak Rate | Zero-leakage at standard operating pressures |
Why Choose High Purity PFA Nitrogen Blowdown System
- Unmatched Material Integrity: Our focus on high-performance fluoropolymers means this system is not just coated, but solid PFA. This provides a lifetime of service in environments that would destroy standard laboratory equipment in weeks.
- Precision CNC Fabrication: Every valve and fitting is manufactured in-house using advanced CNC machining processes. This ensures dimensional accuracy and a level of seal integrity that mass-produced components cannot match.
- Total Customization Capabilities: We understand that every laboratory workflow is unique. Whether you require a specific number of positions, unique bottle dimensions, or integrated heating jackets, our engineering team can provide a bespoke solution.
- Proven Reliability in Semiconductor Grades: Trusted by the world's leading semiconductor and analytical facilities, our systems are the industry benchmark for trace-metal-free sample preparation.
- Responsive Technical Support: Choosing this equipment means gaining a partner in your laboratory's success. We provide comprehensive support from initial configuration to long-term maintenance.
For a technical consultation or a formal quotation tailored to your specific laboratory requirements, please contact our engineering department today.
Trusted by Industry Leaders
Product Datasheet
PFA Nitrogen Blowdown System 4-Position 6-Position Corrosion Resistant Multi Sample Evaporator with Customizable PFA Valves
REQUEST A QUOTE
Our professional team will reply to you within one business day. Please feel free to contact us!
Related Products
High Purity PFA Nitrogen Blowdown Evaporator System Corrosion Resistant Sample Concentration Device with Integrated PFA Valves and Customizable Multiple Position Manifolds
Optimize sample concentration with this high-purity PFA nitrogen blowdown system featuring superior chemical resistance, integrated PFA valves, and customizable multi-position bottle configurations designed for trace analysis and demanding laboratory environments across semiconductor and environmental sectors.
High Purity PFA Nitrogen Purge System Corrosion Resistant 4 and 6 Position Evaporation Setup Customizable Laboratory Trace Analysis Equipment
High-purity PFA nitrogen purge system designed for corrosive sample preparation in trace analysis. This customizable unit features integrated PFA valves and multi-position bottle configurations, ensuring zero metal contamination and exceptional chemical resistance for semiconductor and environmental laboratory applications.
High Purity PFA Inert Gas Purge Device for Semiconductor Precursor Trace Analysis Nitrogen and Argon Compatible Purging System
Ultra-high purity PFA inert gas purging device for semiconductor precursor detection and trace analysis. Engineered for nitrogen or argon purging to prevent sample oxidation and contamination in critical laboratory workflows. Durable chemical-resistant construction for professional research.
High Purity PFA Constant Pressure Condensation Reaction System Acid Resistant High Temperature Customizable Teflon Labware
Engineered for extreme purity, this PFA constant pressure condensation reaction system offers unparalleled acid resistance and thermal stability. Fully customizable for ultra-trace analysis and semiconductor applications, ensuring sample integrity in the most demanding industrial and laboratory environments.
Corrosion Resistant PFA Bottle Top Dispenser Translucent Squeeze Liquid Extraction System for Ultra Pure Chemical Handling
High-purity PFA bottle-top dispensers offer exceptional chemical resistance and translucent visibility for safe squeeze extraction. Ideal for trace analysis and corrosive fluid handling, these custom-engineered systems ensure clean, precise liquid delivery without risk of external contamination or manual operator spills.
PFA Sub Boiling Acid Purifier Electronic Grade Distillation System Laboratory Trace Analysis Equipment
Engineered for the continuous 48-hour preparation of ultra-trace electronic-grade acids this high-purity PFA sub-boiling distillation system ensures maximum chemical resistance and non-contaminating performance for demanding laboratory trace analysis environments and semiconductor chemical processing workflows with bespoke configurations available.
High Purity PFA Chromatography Column Double Layer Constant Pressure Filtration System with Sieve Plate for Strong Acid Resistance
Optimize trace analysis with this high-purity PFA chromatography column. Featuring a double-layer constant pressure design and integrated sieve plate, it provides superior acid resistance and replaces traditional glass sand cores for demanding laboratory and industrial filtration applications worldwide.
PTFE PFA Vacuum Filtration System Corrosion Resistant Customizable Shatterproof Laboratory Device
High-performance PTFE and PFA vacuum filtration systems designed for extreme chemical resistance. This customizable, shatterproof unit ensures trace-level purity and exceptional thermal stability for demanding laboratory processes and hazardous fluid transfers in industrial and research applications.
High Purity PFA Acid Purifier Maintenance and Refurbishment System with Silicone Heating Jacket and Digital Temperature Control Box
Enhance laboratory efficiency with our comprehensive maintenance and refurbishment solutions for high-purity PFA acid purification systems. This precision-engineered service includes specialized silicone heating jackets, replacement collection bottles, and advanced temperature control units for demanding trace analysis workflows. Ensure peak performance.
High Purity PFA Chromatography Column with Collection Bottle Corrosion Resistant Fluoropolymer Filtration System for Trace Analysis
High-performance PFA chromatography column and collection bottle system offers exceptional chemical resistance and ultra-low metal ion leaching for trace analysis. Durable corrosion-resistant fluoropolymer construction serves as a premium glass alternative for demanding laboratory filtration and high-purity purification.
PTFE Acid Steam Cleaning System HF Resistant Trace Analysis Beaker Digestion Tank Customizable
Precision-engineered PTFE acid steam cleaning systems provide contaminant-free trace analysis environments. These high-purity PFA systems resist hydrofluoric acid, ensuring non-polluting results for digestion tanks and laboratory beakers through automated, customizable vapor cleaning protocols for demanding scientific laboratory research.
Translucent PFA Bottle Top Dispenser for Corrosion Resistant Chemical Squeeze Extraction
Engineered high-purity PFA bottle top dispenser designed for corrosion-resistant squeeze extraction. This translucent fluoropolymer system ensures contamination-free liquid handling and safe chemical transfer in demanding laboratory environments. Fully customizable designs available for specialized industrial research.
Custom PTFE Acid Resistant Support Rack Multi Hole PFA Hydrogen Absorption System Bracket
Professional custom PTFE and PFA support racks specifically engineered for high-purity hydrogen absorption systems. These acid-resistant multi-hole brackets ensure superior chemical stability, gas integrity, and long-term durability in demanding industrial electrolysis, laboratory research, and fuel cell testing environments.
High Purity PFA Reaction Vessel 4L Water Oxygen Separation Tank for Proton Exchange Membrane Electrolysis Experiments Customizable Laboratory Fluid Component
Optimize PEM electrolysis research with our 4L high-purity PFA water-oxygen separation tank. Engineered for total chemical inertness, this customizable vessel prevents catalyst poisoning and membrane degradation, ensuring high-accuracy experimental results in demanding electrochemical and industrial green hydrogen laboratory applications.
High Purity PFA Gas Washing Bottle Custom Gas Scrubbing Unit with PTFE Bubbling Ball and Trace Analysis Absorption Vessel
Premium PFA gas washing bottle featuring PTFE bubbling balls for high-purity gas scrubbing. Designed for trace analysis and corrosive gas filtration, these customizable absorption units ensure zero contamination and superior chemical resistance for critical laboratory processes and industrial applications.
Corrosion Resistant PTFE Support with PFA Transparent Reaction Tank and High Purity PFA Sampling Tube for Trace Analysis
Optimized for trace analysis and corrosive chemical processing this high purity PTFE support and transparent PFA reaction system ensures zero heavy metal contamination custom engineered for laboratories demanding superior chemical resistance and precision fluid transfer in sensitive industrial applications
Corrosion Resistant High Purity PFA Valve and Weldable Transparent Tubing for Semiconductor Fluid Transfer
Ensure ultra-pure fluid transfer with our corrosion-resistant PFA valves and weldable transparent tubing. Engineered for semiconductor and sensor manufacturing, these non-leaching components offer universal chemical resistance and exceptional thermal stability for the most demanding high-purity industrial applications.
High Purity PFA Gas Washing Bottle Corrosion Resistant Gas Absorption Vessel PTFE Cap Customizable PFA Reaction Bottle
Engineered for extreme chemical environments, this high-purity PFA gas washing bottle features a precision-fitted PTFE cap. Ideal for trace analysis and corrosive gas absorption, this customizable system ensures zero contamination and superior reliability in demanding laboratory workflows.
High Purity PFA Gas Washing Bottle with PTFE Bubbling Ball for Trace Analysis and Custom Gas Filtration
High-purity PFA gas washing bottles with PTFE bubbling balls offer contaminant-free gas filtration for trace analysis. These customizable absorption units provide superior chemical resistance and zero precipitation for demanding laboratory and industrial gas scrubbing applications.
High Purity PFA Gas Washing Bottle Corrosion Resistant Tail Gas Absorption and Buffer Vessel
Premium PFA gas washing bottles and tail gas absorption vessels offer ultimate chemical resistance and ultra-trace purity. These customizable buffer bottles ensure zero contamination for demanding laboratory applications, semiconductor processing, and high-precision chemical analysis and research.