Products PTFE(Teflon) Products PTFE(Teflon) Labware High Purity PFA Chromatography Column Double Layer Constant Pressure Filtration System with Sieve Plate for Strong Acid Resistance
Toggle Categories
High Purity PFA Chromatography Column Double Layer Constant Pressure Filtration System with Sieve Plate for Strong Acid Resistance

PTFE(Teflon) Labware

High Purity PFA Chromatography Column Double Layer Constant Pressure Filtration System with Sieve Plate for Strong Acid Resistance

Item Number : PL-CP394

Price varies based on specs and customizations


Material
High-Purity Perfluoroalkoxy (PFA)
Temperature Range
-200°C to +260°C
Customization
Fully Bespoke CNC Fabrication
ISO & CE icon

Shipping:

Contact us to get shipping details Enjoy On-time Dispatch Guarantee.

View Specs

Why Choose Us

Easy ordering process, quality products, and dedicated support for your business success.

Easy Process Quality Assured Dedicated Support

Product Overview

Product image 1

Product image 4

This high-purity chromatography system represents the pinnacle of fluoropolymer engineering, designed specifically to meet the rigorous demands of trace analysis and aggressive chemical processing. Constructed entirely from premium Perfluoroalkoxy (PFA), this unit provides an chemically inert environment that is essential for laboratories handling highly corrosive reagents. By utilizing a double-layer constant pressure architecture, the equipment ensures a steady and controlled flow rate, which is critical for achieving reproducible results in complex separation and filtration tasks.

Targeting industries such as semiconductor manufacturing, geochemistry, and environmental monitoring, this system serves as a robust alternative to traditional glass and quartz apparatus. The integration of a precision-machined sieve plate eliminates the common points of failure found in bonded glass sand cores, providing a seamless and easy-to-clean solution for particulate removal. This unit is engineered to withstand extreme chemical environments where standard labware would fail, offering unparalleled longevity and performance reliability.

In demanding industrial and research settings, confidence in equipment is paramount. This system is manufactured through advanced CNC machining processes, ensuring dimensional accuracy and structural integrity that exceeds industry standards. Whether used for ion exchange chromatography or high-purity sample preparation, the equipment maintains its physical and chemical properties even when exposed to concentrated hydrofluoric acid, nitric acid, and various organic solvents. This makes it an indispensable tool for facilities committed to maintaining the highest levels of sample purity and operational uptime.

Key Features

  • Exceptional Chemical Inertness: Fabricated from virgin PFA resin, the unit exhibits near-universal chemical resistance, making it suitable for handling the most aggressive acids, bases, and solvents without risk of degradation or sample contamination.
  • Double-Layer Constant Pressure Design: The specialized architecture allows for a regulated fluid head, ensuring consistent flow dynamics throughout the filtration or separation process, which is vital for the accuracy of column chromatography.
  • Integrated PFA Sieve Plate: This feature serves as a direct, high-performance replacement for traditional glass sand cores; it provides superior mechanical strength and eliminates the leaching of ions common in silicate-based filters.
  • High Thermal Stability: The system operates reliably across a wide temperature range, from cryogenic levels up to 260°C, allowing for hot acid digestions and high-temperature filtration procedures without structural compromise.
  • Precision-Machined Components: Every part of the unit is crafted using high-end CNC technology, resulting in smooth interior surfaces that minimize sample hold-up and facilitate rapid, thorough cleaning between batches.
  • Non-Stick Surface Properties: The ultra-low surface energy of PFA prevents residues and particulates from adhering to the column walls or the sieve plate, significantly reducing the risk of cross-contamination in trace analysis applications.
  • Enhanced Durability: Unlike fragile glass or quartz alternatives, this system is impact-resistant and less prone to breakage under mechanical or thermal shock, reducing long-term replacement costs and laboratory waste.
  • Bespoke Customization: Each unit can be tailored to specific dimensional requirements, including custom column lengths, diameters, and sieve plate pore sizes, to meet the unique needs of specialized experimental setups.
  • Zero Metallic Contamination: The manufacturing process ensures that no metallic catalysts or impurities are introduced, which is critical for ultra-trace element determination in the parts-per-trillion (ppt) range.
  • Easy Assembly and Maintenance: The modular design allows for quick disassembly, enabling users to inspect and clean internal components easily, ensuring the system remains in peak condition for every run.

Applications

Application Description Key Benefit
Semiconductor Processing Filtration and purification of high-purity photolithography chemicals and etching reagents. Prevents metallic ion contamination in ultra-clean environments.
Geochemical Trace Analysis Column separation of rare earth elements and isotopes from mineral samples dissolved in strong acids. Withstands concentrated HF and HNO3 while maintaining low background levels.
Nuclear Medicine Separation of radioactive isotopes for diagnostic and therapeutic pharmaceutical production. High radiation resistance and easy decontamination of PFA surfaces.
Environmental Testing Sample preparation for the detection of heavy metals in wastewater and industrial effluents. Replaces glass to eliminate silica leaching and sample absorption.
Pharmaceutical Synthesis Fine chemical filtration during the synthesis of aggressive or high-purity active ingredients. Ensures batch consistency and prevents chemical reaction with vessel material.
Petrochemical Research Analysis of corrosive catalysts and heavy oil fractions in high-temperature environments. Maintains structural integrity at elevated temperatures up to 260°C.
Battery Technology R&D Processing of electrolyte materials and high-purity lithium salts for next-generation energy storage. Superior resistance to organic solvents and reactive chemical species.

Technical Specifications

Parameter Specification Detail (Model: PL-CP394)
Material Construction 100% High-Purity Perfluoroalkoxy (PFA)
Design Configuration Double-layer, Constant Pressure Chamber Design
Filtration Interface Integrated PFA Sieve Plate (Replaceable or Fixed)
Alternative Capability Direct Replacement for Porous Glass / Sand Core Filters
Temperature Range -200°C to +260°C (-328°F to +500°F)
Chemical Resistance Universal (including Hydrofluoric, Nitric, and Sulfuric Acids)
Dimensions (Diameter/Height) Fully Customizable Based on Project Requirements
Sieve Plate Pore Size Bespoke Machined to Specification
Connection Types Threaded, Flanged, or Push-fit PFA Connections Available
Surface Finish High-Precision CNC Machined Mirror Surface

Why Choose This Product

Selecting this PFA chromatography system is an investment in uncompromising laboratory accuracy and long-term durability. Unlike standard glass solutions that are prone to cracking and ion leaching, this unit utilizes high-performance fluoropolymers that provide a chemically sterile environment for your most sensitive samples. The precision of our CNC fabrication ensures that every constant pressure column meets exacting tolerances, delivering the repeatable performance required for modern trace analysis and industrial processing.

Furthermore, the robust nature of PFA means that this equipment will outlast traditional materials by years, significantly lowering the total cost of ownership. The ability to fully customize the dimensions and configurations of the PL-CP394 series allows us to solve specific fluid handling challenges that off-the-shelf products cannot address. Our commitment to using only the highest grade of PFA ensures that your data remains untainted by impurities, providing the confidence needed for mission-critical research and production.

Our engineering team is ready to assist you in designing a bespoke solution that fits your exact workflow and chemical compatibility needs. Please contact our technical sales department today to request a quote or to discuss your custom specifications for high-purity laboratory equipment.

Trusted by Industry Leaders

Our Cooperated Clients
View more faqs for this product

Product Datasheet

High Purity PFA Chromatography Column Double Layer Constant Pressure Filtration System with Sieve Plate for Strong Acid Resistance

Category Catalog

Ptfe(Teflon) Labware


REQUEST A QUOTE

Our professional team will reply to you within one business day. Please feel free to contact us!

Related Products

High Purity PFA Chromatography Column Double Layer Constant Pressure Filter Column with Sieve Plate Acid Resistant Fluoropolymer Filtration System

High Purity PFA Chromatography Column Double Layer Constant Pressure Filter Column with Sieve Plate Acid Resistant Fluoropolymer Filtration System

Advanced high-purity PFA chromatography columns featuring double-layer constant pressure design and integrated sieve plates. This acid-resistant filtration system effectively replaces traditional glass sand cores for ultra-trace analysis in semiconductor, geological, and high-performance chemical manufacturing industrial environments globally.

View Details
High Purity PFA Chromatography Columns Series Filtration Resin Ion Exchange System with Sieve Plate Rack Customizable Corrosion Resistant Laboratory Fluid Handling

High Purity PFA Chromatography Columns Series Filtration Resin Ion Exchange System with Sieve Plate Rack Customizable Corrosion Resistant Laboratory Fluid Handling

Engineered for trace analysis and semiconductor applications, these high-purity PFA chromatography columns offer exceptional corrosion resistance and modular series connectivity. Featuring customizable sieve plate racks and bespoke dimensions, our systems ensure ultra-clean resin exchange and precise fluid separation.

View Details
High Purity PFA Chromatography Resin Exchange Column System with Series Filtration and Integrated Sieve Plate Rack Corrosion Resistant Laboratory Purification Equipment

High Purity PFA Chromatography Resin Exchange Column System with Series Filtration and Integrated Sieve Plate Rack Corrosion Resistant Laboratory Purification Equipment

High-purity PFA chromatography and resin exchange column system featuring series filtration, sieve plate supports, and extreme chemical resistance. Precision-engineered for trace metal analysis and corrosive fluid processing. Fully customizable dimensions and configurations for advanced laboratory workflows.

View Details
High Purity PFA Chromatography Column and Collection Bottle System Corrosion Resistant Filter Column with Sieve Plate Glass Alternative

High Purity PFA Chromatography Column and Collection Bottle System Corrosion Resistant Filter Column with Sieve Plate Glass Alternative

Upgrade your lab with our high-purity PFA chromatography column system. This corrosion-resistant glass alternative features an integrated sieve plate and collection bottle, ensuring ultra-trace analysis integrity through superior chemical inertness and custom CNC fabrication for demanding industrial applications.

View Details
Translucent PFA Ion Exchange Column with Sieve Plate for Corrosive Chemical Processing and High Purity Trace Analysis

Translucent PFA Ion Exchange Column with Sieve Plate for Corrosive Chemical Processing and High Purity Trace Analysis

Enhance trace analysis using this translucent PFA ion exchange column featuring integrated sieve plates for superior chemical resistance and visual monitoring. Fully customizable for high-purity laboratory applications and aggressive chemical processing environments. Request your bespoke industrial solution today for performance.

View Details
High Purity PFA Filtration Bottle with Integrated Sieve Plate and Squeezable Body for Trace Analysis

High Purity PFA Filtration Bottle with Integrated Sieve Plate and Squeezable Body for Trace Analysis

Premium PFA filtration bottles feature integrated sieve plates and squeeze-action dispensing for high-purity trace analysis. These customizable units ensure zero contamination and extreme chemical resistance in semiconductor and environmental laboratory workflows.

View Details
High Purity PFA Chromatography Microcolumn Corrosion Resistant Resin Column with Sieve Plate for Trace Analysis

High Purity PFA Chromatography Microcolumn Corrosion Resistant Resin Column with Sieve Plate for Trace Analysis

Premium PFA chromatography microcolumns for ultra-trace analysis. Featuring one-piece molded construction, superior chemical resistance, and customizable sieve plates, these columns ensure zero contamination and exceptional durability in the most demanding laboratory environments and industrial chemical processes.

View Details
High Purity PFA Chromatography Column with Collection Bottle Corrosion Resistant Fluoropolymer Filtration System for Trace Analysis

High Purity PFA Chromatography Column with Collection Bottle Corrosion Resistant Fluoropolymer Filtration System for Trace Analysis

High-performance PFA chromatography column and collection bottle system offers exceptional chemical resistance and ultra-low metal ion leaching for trace analysis. Durable corrosion-resistant fluoropolymer construction serves as a premium glass alternative for demanding laboratory filtration and high-purity purification.

View Details
High Purity PFA Filtration Reagent Bottle with Squeezable Body and Integrated Bottom Sieve Plate for Trace Analysis

High Purity PFA Filtration Reagent Bottle with Squeezable Body and Integrated Bottom Sieve Plate for Trace Analysis

Engineered from ultra-high purity PFA, this squeezable filtration bottle features an integrated bottom sieve plate for trace analysis. Ensure ultra-low metal ion background and exceptional chemical resistance for demanding laboratory applications and high-sensitivity sample preparation and filtration analytical workflows.

View Details
PTFE Corrosion Resistant Filter with PFA Valve Connections and Integrated Sieve Plate

PTFE Corrosion Resistant Filter with PFA Valve Connections and Integrated Sieve Plate

High-performance PTFE filtration system featuring PFA valve connections and customizable sieve plates for extreme chemical resistance. Ideal for pharmaceutical and semiconductor processes requiring absolute purity, durability, and bespoke engineering solutions for aggressive fluid handling.

View Details
High Purity PFA Chromatography Columns and Collection Bottles Corrosion Resistant Fluoropolymer Filtration Systems for Trace Analysis

High Purity PFA Chromatography Columns and Collection Bottles Corrosion Resistant Fluoropolymer Filtration Systems for Trace Analysis

Optimize high-purity trace analysis with our customizable PFA chromatography columns and collection bottles. Engineered for extreme corrosion resistance and ultra-low metal leaching, these fluoropolymer systems replace glass in demanding laboratory workflows and semiconductor-grade chemical processing applications for industry professionals worldwide.

View Details
High Purity PFA Ion Exchange Column Corrosion Resistant High Purity Chromatography Glass Alternative Customizable Vessel

High Purity PFA Ion Exchange Column Corrosion Resistant High Purity Chromatography Glass Alternative Customizable Vessel

This high-purity PFA ion exchange column provides exceptional chemical resistance and transparency for trace analysis. A customizable glass alternative, it ensures zero contamination for semiconductor and pharmaceutical laboratories requiring precise, bespoke fluid separation solutions and ultimate durability.

View Details
High Purity PFA Condenser Serpentine Straight HF Resistant Reaction Apparatus Custom Circulation Column

High Purity PFA Condenser Serpentine Straight HF Resistant Reaction Apparatus Custom Circulation Column

Engineered for semiconductor and trace analysis, these custom PFA condensers and reaction columns offer unrivaled HF resistance and high-temperature stability. Our CNC-fabricated laboratory solutions ensure maximum purity and chemical compatibility for demanding industrial chemical processing and research applications.

View Details
PFA Chromatography Column Series and Corrosion Resistant Resin Exchange Column with Filter Frit Support for Trace Analysis Customizable

PFA Chromatography Column Series and Corrosion Resistant Resin Exchange Column with Filter Frit Support for Trace Analysis Customizable

High-purity PFA chromatography column series featuring corrosion-resistant resin exchange capabilities and customizable filter frit supports. Engineered for trace analysis and aggressive chemical processing, this system ensures zero contamination and superior chemical stability in demanding laboratory environments.

View Details
High Purity PFA Water Cooled Micro Chromatography Column Corrosion Resistant High Temperature Thermal Condensation System

High Purity PFA Water Cooled Micro Chromatography Column Corrosion Resistant High Temperature Thermal Condensation System

Premium PFA micro chromatography column with integrated water-cooling jacket provides rapid condensation and exceptional chemical resistance. Engineered for high-purity trace analysis and corrosive chemical separation, ensuring zero contamination and long-term structural integrity in demanding laboratory environments.

View Details
High Purity PFA Constant Pressure Condensation Reaction System Acid Resistant High Temperature Customizable Teflon Labware

High Purity PFA Constant Pressure Condensation Reaction System Acid Resistant High Temperature Customizable Teflon Labware

Engineered for extreme purity, this PFA constant pressure condensation reaction system offers unparalleled acid resistance and thermal stability. Fully customizable for ultra-trace analysis and semiconductor applications, ensuring sample integrity in the most demanding industrial and laboratory environments.

View Details
Custom PTFE Distillation Chromatography Filtration Columns for Semiconductor Chemical Analysis and Corrosion Resistant Lab Processing

Custom PTFE Distillation Chromatography Filtration Columns for Semiconductor Chemical Analysis and Corrosion Resistant Lab Processing

Discover high-performance custom PTFE distillation and chromatography filtration columns engineered for ultra-pure semiconductor lab analysis. Our corrosion-resistant laboratory solutions provide exceptional chemical stability and plasma resistance for demanding trace metal analysis and industrial-grade chemical purification applications.

View Details
PTFE PFA Vacuum Filtration System Corrosion Resistant Customizable Shatterproof Laboratory Device

PTFE PFA Vacuum Filtration System Corrosion Resistant Customizable Shatterproof Laboratory Device

High-performance PTFE and PFA vacuum filtration systems designed for extreme chemical resistance. This customizable, shatterproof unit ensures trace-level purity and exceptional thermal stability for demanding laboratory processes and hazardous fluid transfers in industrial and research applications.

View Details
Corrosion Resistant PFA Bottle Top Dispenser Translucent Squeeze Liquid Extraction System for Ultra Pure Chemical Handling

Corrosion Resistant PFA Bottle Top Dispenser Translucent Squeeze Liquid Extraction System for Ultra Pure Chemical Handling

High-purity PFA bottle-top dispensers offer exceptional chemical resistance and translucent visibility for safe squeeze extraction. Ideal for trace analysis and corrosive fluid handling, these custom-engineered systems ensure clean, precise liquid delivery without risk of external contamination or manual operator spills.

View Details
Custom PTFE Filtration System Acid Resistant High Purity Semiconductor Grade Chemical Processing Filter

Custom PTFE Filtration System Acid Resistant High Purity Semiconductor Grade Chemical Processing Filter

Optimized for semiconductor and chemical processing, this customizable PTFE filtration system offers unparalleled acid resistance and high-purity performance. Engineered for demanding industrial environments, our bespoke solutions ensure zero contamination and exceptional long-term durability in highly corrosive media.

View Details