Battery Testing Fixtures & Molds
PTFE Electrochemical Electrode Holder for Thickened Samples with Platinum Contact Sheet
Item Number : PL-DJ43
Price varies based on specs and customizations
- Rod Material
- Polytetrafluoroethylene (PTFE) / PEEK (Optional)
- Conductive Medium
- High-purity Platinum (Pt) Sheet / Gold (Au) / Glassy Carbon
- Clamping Mechanism
- Double-bolt fixation for thickened samples
Shipping:
Contact us to get shipping details Enjoy On-time Dispatch Guarantee.
Why Choose Us
Easy ordering process, quality products, and dedicated support for your business success.
Product Overview


This high-performance sample holder represents the pinnacle of specialized laboratory hardware, specifically engineered to accommodate thickened sample plates and sheets within complex electrochemical analysis setups. By combining the unmatched chemical resistance of premium polytetrafluoroethylene with the superior electrical performance of a high-purity noble metal contact, this holder ensures reliable and noise-free data acquisition. The integration of a double-bolt clamping mechanism provides a robust solution for researchers and industrial procurement teams who require stable sample placement without risking material deformation or experimental contamination.
Designed for highly specialized research environments, this system finds extensive utility in energy storage, corrosion monitoring, electroplating, and catalyst testing across both academic laboratories and advanced R&D divisions of chemical, metallurgical, and electronics manufacturers. Whether deployed in highly acidic electrolyte baths or subjected to organic solvents, the structural integrity of the polymer housing remains entirely unaffected. This structural stability guarantees that your critical test samples are held securely in a parallel alignment, preserving optimal spatial geometry relative to the counter and reference electrodes.
Reliability in demanding conditions is the cornerstone of our engineering philosophy. Every component of the clamp is designed to prevent fluid entrapment and withstand harsh chemical environments, including prolonged exposure to strong mineral acids and highly alkaline solutions. By selecting this robust sample holding system, research institutions and industrial testing facilities can confidently run long-duration experiments, knowing that the contact resistance, mechanical grip, and sample positioning will remain constant from the initial potential sweep to the final impedance measurement cycle.
Key Features
- Premium PTFE Electrode Stem: Machined from high-density, laboratory-grade polytetrafluoroethylene to ensure complete chemical inertness and resistance to aggressive reagents. This robust housing prevents chemical leaching or contamination, ensuring that the electrochemical integrity of the electrolyte and sample remains completely pristine throughout testing.
- Reinforced Double-Bolt Fixation: Features a dual-screw mechanical clamping design that applies uniform, balanced pressure across the entire width of the sample. This configuration prevents sample slippage, mitigates mechanical deformation, and maintains stable physical alignment under continuous fluid agitation.
- Optimized for Thickened Samples: Engineered with an expanded clamp opening and robust jaw structure specifically tailored to hold thick substrates, metal plates, and ceramic-backed films. This design eliminates the limitations of standard low-profile clips, allowing researchers to evaluate a broader range of industrial materials.
- High-Purity Platinum Contact Sheet: Equipped with an integrated, high-conductivity platinum contact sheet that ensures excellent electrical coupling with the working electrode sample. The noble metal contact prevents oxidation, minimizes contact resistance, and guarantees exceptionally low electrical noise during precise measurements.
- Single-Block CNC Precision Machining: Fabricated via advanced end-to-end CNC machining processes from solid stock materials rather than being molded. This construction method avoids internal stresses, prevents micro-cracks, and results in a seamless surface that is exceptionally easy to clean and maintain.
- Outstanding Thermal and Mechanical Endurance: Designed to function flawlessly across a wide operating temperature envelope, maintaining its structural rigidity and clamping force without softening. This ensures reliable performance in both cryogenic test environments and high-temperature electrochemical reactor cells.
- Versatile Structural Options: Built with modular compatibility in mind, allowing the body to be constructed of alternative materials such as PEEK for high-pressure applications. For physical tests requiring high mechanical torque, metal-bodied versions can also be produced from single blocks of stainless steel, copper, or titanium.
- Customizable Contact Materials: Provides the flexibility to swap the standard platinum contact sheet with gold or glassy carbon alternatives depending on the specific potential windows and chemical environments of your tests. This adaptability makes it a versatile tool for wide-ranging electrochemical studies.
Applications
This specialized clamp is utilized across a wide variety of electrochemical research fields and industrial quality control departments. The table below outlines several real-world applications where this robust clamping mechanism is critical:
| Application | Description | Key Benefit |
|---|---|---|
| Corrosion Testing in Acidic Media | Evaluation of thick metal alloy plates or coated substrates in sulfuric or hydrochloric acid solutions. | Complete chemical inertness of the PTFE body prevents galvanic corrosion or contamination of the bath. |
| Battery & Supercapacitor R&D | Secure mounting of thick electrode plates, polymer membranes, or composite substrates in organic electrolytes. | Stable mechanical grip ensures uniform current distribution and highly reproducible impedance measurements. |
| Electrodeposition & Electroplating | Holding structural metal or semiconductor plates during electroplating processes with high current densities. | Dual-bolt clamping maintains low contact resistance, ensuring even coating thickness and uniform deposition. |
| Sensor Development | Integration of custom thick-film or ceramic sensors into electrochemical measurement cells. | Precision alignment and reliable platinum contacts ensure highly sensitive and low-noise electrical signals. |
| Fuel Cell Catalyst Evaluation | Testing the performance of catalyst-coated gas diffusion layers (GDLs) or thicker membrane electrode assemblies. | Prevents mechanical crushing while ensuring secure electrical connectivity across the active surface area. |
| Metallographic Testing | Conducting polarization measurements on cut, mounted metallographic cross-sections of varying thicknesses. | Adjustable jaw accommodates irregular, thick samples while providing solid electrical contact to the polished face. |
Technical Specifications
To meet the precise demands of advanced research, this electrode holder is manufactured to strict dimensional tolerances and material standards. Below is the detailed specification matrix for the PL-DJ43 series and its customizable variants:
Material and Dimensional Configurations
| Parameter Group | Technical Specification | Configuration Details (PL-DJ43) |
|---|---|---|
| Model Reference | Product Item Number | PL-DJ43 |
| Structural Body & Rod | Standard Material | Polytetrafluoroethylene (PTFE) |
| Optional Engineering Plastics | Polyetheretherketone (PEEK) | |
| Optional Metal Clamps | Stainless Steel, Copper, Titanium (machined from solid block) | |
| Conductive Medium | Standard Contact Plate | Pure Platinum (Pt) Sheet |
| Optional Contact Plates | Pure Gold (Au) Sheet, Glassy Carbon (GC) Sheet | |
| Clamping Design | Fixation Type | Double-bolt (dual-screw) adjustment |
| Target Sample Thickness | Thickened sheets, plates, and blocks (up to 10 mm standard) | |
| Dimensions & Sizing | Standard Stem Diameter | 6.0 mm / 8.0 mm (customizable) |
| Standard Stem Length | 100 mm / 120 mm (customizable) | |
| Operating Performance | Temperature Range (PTFE Body) | -100°C to +250°C |
| Temperature Range (PEEK Body) | -50°C to +300°C | |
| Chemical Compatibility | Near-universal (resistant to acids, bases, organic solvents) |
Note: Custom stem diameters, alternative rod lengths, and specialized clamp geometries can be custom-machined via our in-house CNC facility to ensure compatibility with proprietary electrochemical cell setups.
Why Choose This Product
- Uncompromising Material Quality: We source only premium-grade raw materials, ensuring that our PTFE housing and noble metal contacts meet the highest standards of purity, density, and chemical stability required for trace analysis.
- Precision CNC Manufacturing: Every single clamp is machined from solid block material under strict quality control guidelines. This eliminates the structural weaknesses, microscopic pores, and residual stresses common in molded or lower-grade laboratory consumables.
- Custom-Tailored Solutions: Thanks to our comprehensive end-to-end CNC capabilities, we do not force you into a one-size-fits-all solution. We can easily customize the physical dimensions, stem lengths, and contact materials to integrate seamlessly with your unique experimental setup.
- Long-Term Operational Economy: The combination of an ultra-durable plastic body and highly stable precious metal contact elements results in an exceptionally long service life, significantly reducing replacement costs and downtime in high-throughput testing facilities.
For customized dimensions, material variations, or bulk order pricing, contact KINTEK today to discuss your project requirements with our technical engineering team.
Trusted by Industry Leaders
Product Datasheet
PTFE Electrochemical Electrode Holder for Thickened Samples with Platinum Contact Sheet
REQUEST A QUOTE
Our professional team will reply to you within one business day. Please feel free to contact us!
Related Products
Replaceable Platinum Electrode Clamp PTFE Corrosion Resistant Sample Holder
High-performance replaceable platinum electrode clamp with PTFE holder and pure platinum connection, offering superior corrosion resistance and electrical conductivity. Standard 80mm length supports 1.5mm samples; fully customizable. Ideal for electrochemistry and corrosion studies. Contact KINTEK for a custom solution.
PTFE Flat Plate Working Electrode Electrochemical Cell for Sheet Samples Corrosion Testing and SEM Sample Preparation
This high purity PTFE electrochemical cell enables precise corrosion testing and SEM preparation for flat sheet samples featuring a customizable one square centimeter exposure area and a robust chemical resistant dual layer clamping design for reliable laboratory research analyses
Customizable Graphite Electrode Clamp PTFE Coated Corrosion Resistant
High-performance graphite electrode clamp with interchangeable sample holders and PTFE coating for superior corrosion resistance. Customizable length and clamping width ensure fit for diverse electrochemical applications. Excellent conductivity and robust construction deliver reliable performance in demanding lab environments.
Rotating Disk Electrode Horizontal Support Stand
High-purity PTFE rotating disk electrode horizontal support stand with leveling base holds up to six electrodes. Engineered for electrochemical research, battery testing, and corrosion analysis, it offers exceptional chemical resistance and stability. Request a quote for custom configurations.
Customizable PTFE Seals Filter Holders for Versatile Applications
Enhance filtration with KINTEK's PTFE-sealed filter holders for leak-proof, chemical-resistant performance in labs and industries. Explore now!
Corrosion Resistant PTFE Photoelectrochemical Cell High Purity All PTFE Three Electrode Test Cell with Quartz Window
High purity PTFE photoelectrochemical cell designed for precise three electrode testing featuring an ultra high transmission detachable quartz window robust leakproof sealing and customizable volumes from thirty to five hundred milliliters for advanced laboratory research and chemical analysis
Straight Five Port Hermetic Electrochemical Cell with Internal Plug In Design and PTFE Lid
Premium high performance straight five port hermetic electrochemical cell with advanced PTFE lids and borosilicate glass. Perfect for precise three electrode laboratory analysis, gas purging, and controlled reactions with absolute sealing integrity.
Sealed Glass Electrochemical Cell with Jacketed Temperature Control and Chemical Resistant PTFE Lid
Optimize your analytical research with our premium five port sealed electrochemical cell featuring a chemical resistant polytetrafluoroethylene lid and jacketed temperature control. Engineered for precise three electrode systems, this robust vessel delivers outstanding reliability for critical laboratory research applications.
Custom PTFE Laboratory Cleaning Basket Carrier High Purity Acid Base Resistant Wafer Holder Low Background Contamination Free Chemical Bath Rack
Discover high-purity custom PTFE cleaning basket carriers designed for semiconductor and trace analysis. These acid-resistant racks ensure zero leaching and ultra-low background levels, providing reliable performance in the most demanding chemical environments for precision laboratory cleaning processes.
Stainless Steel Electrode Clip with Replaceable Tips for Electrochemical Research
High-quality stainless steel electrode clip designed for secure sample holding in electrochemical cells. Features replaceable electrode tips and customizable dimensions for versatile lab use. Ideal for cyclic voltammetry, corrosion studies, and battery testing. Reliable electrical contact, 80mm length, customizable.
PTFE Membrane Filter Holder for Aerosol Environmental Monitoring and Low Concentration Particulate Matter Sampling Chemical Resistant Air Quality Analysis Component
Engineered for high-purity aerosol collection this PTFE membrane filter holder ensures chemical inertness during low-concentration particulate matter sampling. Compatible with vacuum pumps it provides a corrosion-resistant solution for demanding environmental monitoring and industrial air quality analysis protocols and research.
All PTFE Photoelectrochemical Cell with Quartz Window for Three Electrode Electrochemistry
Discover our premium all PTFE photoelectrochemical cell designed for advanced three electrode testing. Featuring a high transmittance detachable quartz window, 360 degree rotatable lid, and secure O ring seals, this chemical resistant unit ensures maximum precision and exceptional durability.
Custom PTFE Electrolytic Cell Corrosion Resistant Low Background Reaction Vessel with Inlet Outlet Ports
Discover professional high-purity custom PTFE electrolytic cells designed for precision electrochemical analysis. Featuring extreme corrosion resistance and low background interference, these reaction vessels offer customizable inlet/outlet ports for seamless integration into demanding industrial or laboratory fluid systems.
Acid Resistant PTFE Button Cell Battery Test Fixture Customizable Machining High Purity Electrochemical Testing Clamp
High-purity PTFE button cell testing fixtures provide exceptional acid resistance and electrical insulation for precise electrochemical analysis. These customizable clamps eliminate stray currents and prevent electrolyte corrosion during rigorous battery research and development processes in demanding labs.
PTFE Silicon Wafer Holder for Acid Etching and Cleaning Process 2 4 6 8 Inch Customizable High Temperature Resistant
High-purity PTFE silicon wafer holders engineered for extreme acid etching and cleaning processes. Optimized for 2 to 8 inch wafers, these robust customizable carriers ensure contamination-free handling and thermal stability in the most demanding semiconductor fabrication environments for B2B procurement.
All PTFE Exchangeable Membrane Electrochemical Cell Dual Chamber Three Electrode Photoelectrochemical Cell for Laboratory Trace Analysis
Optimize your laboratory testing with this premium all PTFE exchangeable membrane electrochemical cell featuring a dual chamber design, precise electrode alignment, and customizable volumes from 30ml to 500ml for demanding research, impedance spectroscopy, and corrosion analysis.
White PTFE Electrolytic Cell with Movable Slider and Insulated Lid for Fluorine Corrosion Resistance
Engineered for extreme chemical resistance this customizable PTFE electrolytic cell features a movable slider and superior insulation ideal for fluorine rich environments ensuring high purity results in semiconductor and electrochemical research applications and advanced manufacturing.
Corrosion Resistant PTFE Electrochemical Cell for New Energy Research Inert Insulating Customizable Lab Reaction Vessel
Professional PTFE electrochemical cell designed for new energy research featuring exceptional chemical inertness and corrosion resistance. Available in 400ml and 1000ml capacities with full customization for advanced battery testing and high-purity trace analysis delivering reliable industrial performance and extreme durability.
PTFE Filter Membrane Holder for Hydrogen Chloride and Water Filtration 90mm Environmental Sampling Clamp Customizable
Optimize your environmental monitoring with our high-purity PTFE filter holder. Designed for 90mm membranes, this customizable unit ensures chemical inertness for hydrogen chloride and water filtration applications. Reliable, durable, and precision-engineered for professional lab results.
PVDF Sample Support Body for Corrosion Testing and Electrochemical Analysis
High-performance PVDF sample support body precisely controls working electrode reaction area for accurate corrosion testing and electrochemical analysis. Built for superior chemical resistance and long-term reliability, ideal for critical laboratory applications. Explore custom configurations to meet your specific experimental requirements.